Section 06 ELECTRICAL SYSTEM Subsection 01 (CHARGING SYSTEM)

TEST ENGINE SPEED

CURRENT

4000 RPM

approx,A

- Read currentIf current is below specification, check magneto (stator) output prior to concluding that rectifier is faulty,Properly reconnect voltage regulatorrectifier wire
- If voltage is above specification, replace voltage reg latorrectifier- If voltage is below specification, check wiring and connections,Properly secure battery,
NOTE: If the battery will not stay charged, the problem can be any of the charging system components, If these all check good, try new voltage reg ulatorrectif ier,

Dynamic Test: Voltage