2006 Bombardier Outlander Max Series Factory Service Manual, Page 206Get this manual

2006 Bombardier Outlander Max Series Factory Service Manual, Page 206

Section 06 ELECTRICAL SYSTEM Subsection 01 (CHARGING SYSTEM)
MODEL Outlander 400 series Outlander 800 se rie s

VOLTAGE, Vdc 15.1 14 .8

PROCEDURES
NOTE: First, ensure that battery is in good condition prior to performing the following test using current inductive ammeter such as Snap-on MT 110For best results, use the multimeter Fluke 111 (PN 529 035 868)
529035868

vmr2006-017-010

OUTLANDER 400 SERIES

If the battery is regularly discharged, check battery and solenoid terminals
VOLTAGE REG LATO RR EeTI FIE R
Outlander 400 Series