Section 04 ENGINE MANAGEMENT (V-810) Subsection 02 (DIAGNOSTIC PROCEDURE)
DESCRIPTION
ENGINE REACTION
ECM will not do memory tracki ng sequence ECM will not do memory tracking sequence No effect
DESCRIPTION OF LIMP HOME EFFECT
Relay shorted to battery
Damaged relay, damaged circuit wires, damaged connector or damaged ECM output pi ns Blown fuse, damaged or disconnected relay, damaged or disconnected circuit wires, damaged ECM output pinsCommunication error between cluster and ECM andor B.U.O.S
Check for approximately 100 ohms between relay pins 85 and 86Check if system circuit 2-B-14 is shorted to 12 Check fuse F4Check for approximately 100 ohms between relay pins 85 and 86Check system circuit 2-B-14Check for damaged circuit between 1-CI-23, 4-B-29 and 2-08-1Check for damaged circuit between 1-CI-24, 4-8-27 and 2-08-2Repla ce cluster if necessaryInstall proper recommended ECU or gauge for vehicle