Section 02 TROUBLESHOOTING Subsection 02 (TROUBLESHOOTING CHART)
SYMPTOM CONDITION TestInspection

BELT DISINTEGRATIONNORMAL USE1Check drive belt lifetime is exceededaClean CVT system and rebuild with new drive belt2Check drive belt identification numberaExcessive belt speed Using unspecified type of beltReplac belt with proper type of belt (refer to TECHNICAL DATA)
3Check if pulley halves are clean aOil on pulley surfacesClean pulley surfaces with fine emery cloth and wipe clean using Pulley Flange Cleaner (PN 413 711 809) and clothbDrivedriven pulley halves are damaged through stones ins ide CVT area Clean pulley surfaces with fine emery cloth, wipe clean with cloth or replace drivedriven pulley halves and beltSYMPTOM COIJDITION TestInspection