Section 04 ELECTRICAL Subsection 03 (STARTING SYSTEM)
STARTING SYSTEM TESTS GENERAL
First ensure the problem is not related to engine mechanical componentsCauses of troubles are not necessarily related to starter but may be due to burnt fuse (main), faulty battery, start button, ignition switch, engine stop switch, starting solenoid, electrical cables or connectionsCheck these components before removing starterConsult also the Starting System Troubleshooting table above for general view of possible problems
Inspect connections and clean as necessarySolenoid condition can be checked with an ohmmeterInstall test probes on large connectors of solenoidMeasure resistance when current is applied to small connectors; if it is more than few ohms, replace solenoidIf solenoid test good, check the electric starterIf starter test good, the NEUTRAL switch can be suspected
Ignition Switch
A quick test to validate it is workingTurn the ignition switch ONIf the lights turn on, the ignition switch is goodOtherwise, refer to IGNITION SYSTEM, for testing procedureIf it tests good, continue the next tests