Section 06 ELECTRICAL Subsection 03 (CHARGING SYSTEM)
Trigger Coil
STATIC TEST Unplug the magneto connectorMeasure the resistance between the proper wiresThe obtained value should be between 190 and 300 MAGNETO CONNECTOR WIRES QUEST SERIES WHITEYELLOW and BLUEYELLOW BLACKYELLOW and YELLOW