2004 Bombardier Quest/Traxter Series Shop Manual, Page 319Get this manual

2004 Bombardier Quest/Traxter Series Shop Manual, Page 319

Section 06 ELECTRICAL Subsection 02 (OVERVIEW)

To remove plug assembly from the header assembly on the MPEM, press both locking tabs then, pull plug
Wire Selection and Preparation
The size of the wires must be 20 to 16 AWG with wire insulation diameter having minimum dimension of 1.7 mm (0.067 in) and maximum dimension of 2.78 mm (0.106 in)The wire strip length shall be 5.1 mm (1364 in)NOTE: When stripping wires, ensure conductor is not nicked, scraped or cutWire stripping tool jaws may leave marks on the surface of the wire insulationIf these marks occur at the location of the wire seal, leakage may resultInsulation surface within 25 mm (1 in) from the tip of the contact must be smooth
V01G0MA

TYPICAL 1AMP connectors 2Identification numbers