Section 05 ELECTRICAL Subsection 02 (OVERVIEW)
SERVICING DEUTSCH CONNECTORS
Waterproof Connector Housing
Female and Male Connector Housing To remove: Using long nose pliers, pull out the lock
NOTE: Before extraction, push wire forward to relieve pressure on retaining tab Insert 4.8 mm (.189 in) wide screwdriver blade inside the front of the contact cavity Pry back the retaining tab while gently pulling wire back, until contact is removedV01G0QA

FEMALE CONNECTOR HOUSING 1Retaining tab
V01G0OA