Section 03 ENGINE Subsection 06 (REWIND STARTER)
GENERAL
At installation, use torque values and Loctite products from the exploded viewClean threads before using Loctite products when reinstalling screws
Untie knot holding rewind starter grip and remove grip
WARNING
Torque wrench tightening specifications must strictly be adhered toLocking devices (ex locking tabs, elastic stop nuts, self-locking fasteners, etc must be installed or replaced with new ones where specifiedIf the efficiency of locking device is impaired, it must be renewed
R400motr220A

1Starter housing 2Rewind starter grip

REWIND STARTER
Removal
Remove RH side panel and engine coverRemove rewind starter mounting bolts no15 and pull rewind starterTo release tension from torsion spring no2: First pull grip no6 and tie knot more than 20 cm (8 in) below it