2002 Traxter Autoshift XL/XT Shop Manual, Page 174Get this manual

2002 Traxter Autoshift XL/XT Shop Manual, Page 174

Section 05 ELECTRICAL Subsection 06 (HYDRAULICELECTRIC SHIFT SYSTEM)
Resetting the Diagnostic Components Register
Before resetting the diagnostic components registers, the MPEM needs to be in the diagnosticcalibration modeThe register is automatically reset when the following sequence is performed: The jumper on the diagnostic connector is removed while the STARTSTOP button is activatedThe MPEM will reset the register (see table ABNORMALITY-DIAGNOSIS COMPONENTS and table ABNORMALITY CONDITIONS) and after it will turn off itselfSummary of all Tasks
TASK 1INDICATOR LIGHTS TEST 2CLUTCH MODULATOR CALIBRATION 3SENSORS AND SOLENOIDS TEST 4GBPS CALIBRATION 5STPS CALIBRATION 6TPS CALIBRATION LED "5" blinks first, through "1" and after "Check Engine" through "Neutral" "Check Engine" blinks "Reverse" is ON "Hi-Lo Beam" blinks "1" and "Hi-Lo Beam" are ON OPERATION This validates all indicator lights are good