SYMPTOM CONDITION TestInspection

STARTER TURNS, BUT ENGINE DOES NOT CRANKNORMAL USE1Check starteraTeeth damagedReplace starter2Check ring gearaExcessively worn ring gearReplace ring gear3Check one way bearing on magnetoaOne way bearing wrongReplace one way bearing