1999-2000 Bombardier Traxter ATV Factory Service Manual, Page 137Get this manual

1999-2000 Bombardier Traxter ATV Factory Service Manual, Page 137

Section 05 ELECTRICAL Subsection 06 (ELECTRIC SHIFT SYSTEM)
Table 3: Abnormality Conditions
CODE ABNORMALITY CONDITION NO1 Short circuit to battery is detected Operating current on the starter output has exceeded the overload thresholdACTION Refer to STARTING SYSTEM 05-04
Short circuit to battery is detectedChange clutching valveRefer to VALVE Operating current on the clutch solenoid output REMOVALINSTALLATION sectionhas exceeded the overload threshold Short circuit to battery is detected Operating current on the clutch modulator valve output has exceeded the overload threshold Short circuit to battery is detected Operating current on the downshift solenoid output has exceeded the overload threshold Short circuit to battery is detected Operating current on the upshift solenoid output has exceeded the overload threshold Programmable parameters are corruptedChange clutch modulator valveRefer to VALVE REMOVALINSTALLATION sectionChange shifting valveRefer to VALVE REMOVALINSTALLATION sectionChange shifting valveRefer to VALVE REMOVALINSTALLATION sectionInstall new MPEMRefer to INSTRUMENTS AND ACCESSORIES 05-07