1999-2000 Bombardier Traxter ATV Factory Service Manual, Page 121Get this manual

1999-2000 Bombardier Traxter ATV Factory Service Manual, Page 121

Section 05 ELECTRICAL Subsection 04 (STARTING SYSTEM)
STARTING SYSTEM TROUBLESHOOTING
SYMPTOM Starter does not turnCAUSE Ignition switch is in the OFF positionBurnt fuseTransmission is not set on the Park or NeutralPoor contact of battery terminal(s) or ground cable connectionsWeak batteryPoor contact or open circuit of: startstop button ignition switch or starting solenoidSTPS (Sub Transmission Position Sensor) is defectiveMPEM is defectiveEngine mechanical problem (ensure that other electric components are good)Starter turns; but does not crank the enginePoor contact of battery terminal(s)Poor battery ground cable connectionBurnt or poor contact of solenoid switch contact discPoor contact of brushBurnt commutatorWorn commutator segmentsShorted armatureWeak brush spring tensionWeak magnetWorn bushingsWeak batteryStarter turns, but overrunning clutch pinion does not mesh with ring gearWorn clutch pinion gearDefective clutchPoor movement of clutch on splinesWorn clutch bushingWorn ring gearStarter motor keeps runningShorted starting solenoid switch windingMelted solenoid contactsSticking or defective starter clutch05-04-6