SUPPLY VOLTAGE 1Disconnect the three-wire connector from the sensor; then select DC Voltage on the multimeter and connect the red tester lead to the orange wire (C) and the black tester lead to the black wire (A) CD707

2Install the needle adapters to the multimeter leads; then select DC Voltage on the multimeter3Connect the red tester lead to the bluebrown wire (B) and the black tester lead to the blackyellow wire (A); then turn the ignition switch ON and observe the meterThe meter should read 0.8-3.0 DC volts

2Turn the ignition switch to the ON positionThe multimeter should read battery voltageIf battery voltage is not indicated, check the 30-amp fuse, wiring harness, or the ignition switch3Remove the red tester lead and connect to the bluebrown wire (B)The multimeter should read approximately 2.5 DC voltsIf the specified voltage is not indicated, check wire connections at the ECU or substitute another ECU to verify the test