! WARNING An overheated battery could explode causing severe injury or deathAlways monitor charging times and charge rates carefullyStop charging if the battery becomes very warm to the touchAllow it to cool before resuming chargingBattery Charging Chart (Constant-Current Charger)

Testing Electrical Components
All of the electrical tests should be made using the Fluke Model 77 Multimeter (pn 0644-559)If any other type of meter is used, readings may vary due to internal circuitryWhen troubleshooting specific component, always verify first that the fuse is good, that the bulb is good, that the connections are clean and tight, that the battery is fully charged, and that all appropriate switches are activatedNOTE: For absolute accuracy, all tests should be made at room temperature (approximately 68 F)
Battery Voltage (DC)
12.5 or more 12.2-12.4 12.0-12.2 11.0-11.9 11.5 or less

Charge State
100 75-99 50-74 25-49 0-24