2008 Arctic Cat 366 ATV Service Manual, Page 95Get this manual

2008 Arctic Cat 366 ATV Service Manual, Page 95

2Select the OHMS position on the tester and connect the red tester lead to the lavenderred wire; then move the gear shift lever to the (reverse) positionThe meter must read less than ohm3Move the red tester lead and shift lever in turn to the light greenred wire and (neutral) position, whiteblack wire and (high) position, and whitered wire and (low) positionThe meter must read less then ohm in all positionsIf not, the gear shift linkage must be adjusted (see Section 2) or the switch must be replaced RESISTANCE (Charging Coil)

! CAUTION
Always disconnect the battery when performing resistance tests to avoid damaging the multimeter
1Set the meter selector to OHMS position2Test between the three black wires for total of three tests3The meter reading must be within specificationRESISTANCE (Trigger Coil)

Stator Coil
VOLTAGE (AC GeneratorRegulated Output) 1Set the meter selector to the DC Voltage position2Connect the red tester lead to the positive battery post; then connect the black tester lead to the negative battery post3With the engine running at constant 3000 RPM (with the headlights on), the meter must show 14-15.5 DC volts