2008 Arctic Cat 366 ATV Service Manual, Page 88Get this manual

2008 Arctic Cat 366 ATV Service Manual, Page 88

Electrical System This section has been organized into sub-sections which show procedures for the complete servicing of the Arctic Cat ATV electrical systemNOTE: Some photographs and illustrations used in this section are used for clarity purposes only and are not designed to depict actual conditions
RPM Limiter
NOTE: The ATV is equipped with CDI that retards ignition timing when maximum RPM is approachedWhen the RPM limiter is activated, it could be misinterpreted as high-speed misfire
SPECIAL TOOLS number of special tools must be available to the technician when performing service procedures in this sectionDescription
Fluke Model 73 Multimeter MaxiClips Peak Voltage Reading Adapter Test PlugError Code List Kit

Testing Electrical Components
All of the electrical tests should be made using the Fluke Model 73 Multimeter and when testing peak voltage, the Peak Voltage Reading Adapter must be usedIf any other type of meter is used, readings may vary due to internal circuitryWhen troubleshooting specific component, always verify first that the fuse(s) are good, that the bulb(s) are good, that the connections are clean and tight, that the battery is fully charged, and that all appropriate switches are activatedNOTE: For absolute accuracy, all tests should be made at room temperature of 68 F