2006 Arctic Cat Y-6/Y-12 50cc and 90cc Service Manual, Page 70Get this manual

2006 Arctic Cat Y-6/Y-12 50cc and 90cc Service Manual, Page 70

3Crank the engine over using the electric starterThe meter must read 190-282 volts Battery
! CAUTION
The battery can be permanently damaged if the cap-strips over the cells are removed
StatorMagneto Coil
Disconnect the two-wire connector in front of the steering postVOLTAGE (No Load)
NOTE: The battery must be at full charge for this test
! WARNING
Anytime service is performed on battery, the following must be observed: keep sparks, open flame, cigarettes, or any other flame awayAlways wear safety glassesProtect skin and clothing when handling batteryWhen servicing battery in enclosed space, keep the area well-ventilatedMake sure venting tube of battery is always open once battery is filled with electrolyte
1Set the meter selector to the AC Voltage position2Connect the red tester lead to the yellow wire; then connect the black tester lead to the white wire3With the rear axle supported and the wheels off the floor, start the engine and run at 3000 RPM or to the RPM limiterThe meter must read 16.0-19.5 voltsRESISTANCE