2006 Arctic Cat DVX 400 Service Manual, Page 102Get this manual

2006 Arctic Cat DVX 400 Service Manual, Page 102

Clutch Lever Position Switch RESISTANCE

VOLTAGE (Charging CoilNo Load)
NOTE: The peak voltage reading adapter must be disconnected for this test
The connector is the black one on the left side near the voltage regulatorNOTE: Test the connector that comes from the engine
! CAUTION
Always disconnect the battery when performing resistance tests to avoid damaging the multimeter
1Disconnect the battery; then disconnect the two-wire connector at the steering post2Set the meter selector to the OHMS position; then connect the black meter lead to the black wire and the red meter lead to the yellowblack wire3Compress the clutch leverThe meter should show less than ohmRelease the clutch lever and verify that the meter shows an open circuit

Magneto Coils
NOTE: All peak voltage tests should be made using the Fluke Model 73 Multimeter (pn 0644-191) with Peak Voltage Reading Adapter (pn 0644-307)If any other type of tester is used, readings may vary due to internal circuitryNOTE: The battery must be at full charge for this test