2006 Arctic Cat DVX 400 Service Manual, Page 99Get this manual

2006 Arctic Cat DVX 400 Service Manual, Page 99

Primary Winding
1Connect the red tester lead to the terminal (with the wire removed); then connect the black tester lead to ground2The meter reading must be within specificationSecondary Winding

1Connect the red tester lead to the high tension lead (plug cap removed); then connect the black tester lead to ground2The meter reading must be within specificationNOTE: If the meter does not show as specified, replace ignition coil
ATV2183

To access the indicator light connector for testing purposes, use the following procedure1Remove the seat and body (see Section 8)2Disconnect the four-wire connector from the main wiring harnessNOTE: For these tests, 12-volt power supply "jumper" should be used to supply power
Spark Plug Cap

1Connect the red tester lead to one end of the cap; then connect the black tester lead to the other end of the cap
WATER TEMPERATURE INDICATOR LIGHT