2001 Arctic Cat ATVs factory service and repair manual, Page 308Get this manual

2001 Arctic Cat ATVs factory service and repair manual, Page 308

6With the 12-volt power supply still connected, then connect the red tester lead to the heavy battery cable terminal; connect the black tester lead to the heavy starter motor cable terminal7The meter must show less than ohm8With the 12-volt power supply disconnected, connect the red tester lead to terminal #3; then connect the black tester lead to terminal #49The meter must show 3.6 ohms 20NOTE: If the meter shows no resistance, the relay is out of tolerance or it must be replaced Fig5-54

ATV0099A

CDI Unit
Negative Meter Lead To:

CDI UNIT ELECTRICAL TEST SPECIFICATIONS (k-ohms)
Positive Meter Lead To:
1Infinity

(250300 cc)
2-10 20-100 1-7 0
50-150 20-80 50-150 20-80 20-80

2-10 20-100 1-7 0