2001 Arctic Cat ATVs factory service and repair manual, Page 289Get this manual

2001 Arctic Cat ATVs factory service and repair manual, Page 289

Accessory ReceptacleConnector
(400500 cc)

NOTE: This test procedure is for either the receptacle or the connectorVOLTAGE

1Set the meter selector to the D.CVoltage positionATV-0053

Testing Electrical Components
All of the electrical tests should be made using the Fluke Model 73 Multimeter (pn 0644-191)If any other type of meter is used, readings may vary due to internal circuitryWhen troubleshooting specific component, always verify first that the fuse(s) are good, that the bulb(s) are good, that the connections are clean and tight, that the battery is fully charged, and that all appropriate switches are activatedNOTE: For absolute accuracy, all tests should be made at room temperature of 68 F